At Classic Aire Care, our dedicated professionals are committed to your comfort! Our award-winning services and stellar reviews attest to the quality of service you will receive!
We offer a full range of HVAC and plumbing services in the Arnold, MO area, including installation, repair, maintenance, and replacement of the systems you depend on every day. We adhere to strict safety and quality standards and proudly offer 24/7 services for emergencies.
Heating Maintenance, Repairs & Replacements
Winters in Missouri are downright miserable without a reliable heating system in your home. Our certified, licensed, and insured HVAC specialists install, repair, maintain, and replace a full range of heating systems, including:
- Furnaces: We can install, repair, maintain, or replace gas and electric furnaces. We’ll help you size the ideal system for your home, optimize furnace performance, and help you enjoy exceptional energy savings year after year.
- Boilers: We can install, repair, maintain, or replace gas boilers, electric boilers, or solid fuel boilers. Our boiler experts can quickly identify problems, perform reliable repairs, perform preventative maintenance, and replace your aging boiler with a modern, energy-efficient alternative.
- Heat Pumps: It’s our pleasure to help you enjoy reliable warmth in winter and exceptional comfort in summer. Our heat pump installation, repair, maintenance, and replacement services are tailored to meet your needs and keep you comfortable in Missouri’s unique climate.
Contact Classic Aire Care online or at (314) 329-1943 to schedule heating service in Arnold, St. Louis, or surrounding areas.
AC Maintenance, Repairs & Replacements
Summers in Missouri are hot and humid, and it is our pleasure to help you cool off and relax. Our cooling and indoor air quality services are customized to meet your needs and desired comfort. We proudly offer the following services in Arnold and surrounding areas:
- Air Conditioners: We can install, repair, maintain, and replace a broad range of air conditioning systems. We will perform comprehensive load calculations, help you stay on top of the manufacturer’s recommended maintenance, and replace your aging system with a modern, eco-friendly replacement.
- Ductless Systems: Ductless mini-splits are a cost-effective, eco-friendly solution that makes it easy to stay comfortable while reducing your utility bills. Our ductless mini-split installation, maintenance, repair, and replacement services will help you enjoy superior comfort and exceptional savings.
Contact Classic Aire Care online or at (314) 329-1943 to schedule air conditioning service in St. Louis, MO.
Plumbing Services
We offer a full range of plumbing services in the area. We can replace your gas, electric, or tankless water heater, repair or replace your backflow preventer, and more. Our services include:
- 24 hours a day, 7 days a week emergency plumbing services
- Pipe repair or replacement services
- Leak detection and repairs
- Clog clearing and pipe relining services
- Tub and shower repairsÂ
- Backflow preventer installations
Contact Classic Aire Care online or at (314) 329-1943 to schedule plumbing services in Arnold, MO.
Why Choose Classic Aire Care?
At Classic Aire Care, we’ve been making people comfortable since 1926! Our NATE-Certified technicians are dedicated to your comfort, and we guarantee superior craft and solutions you can depend on. When you choose our team, you will always enjoy:
- 100% satisfaction guarantee on installations
- Classic ultimate quality guarantee
- Free estimates
- Exceptional service agreements
- 24 hours a day, 7 days a week emergency service
- And more!Â
Contact Classic Aire Care online or at (314) 329-1943 for fast, reliable, and effective HVAC and plumbing services in Arnold, MO!
FAQs
Why is my AC running but not cooling?
Your AC has several components that operate independently; if the evaporator coils freeze or something compromises a heat exchanger, you’ll get air, but it won’t be cool. If the blower breaks, you’ll have cool refrigerant in place but no air blowing it out.
How often should I schedule HVAC maintenance?
As a general rule, you should have your home’s HVAC system inspected and serviced at least once a year. Twice a year (once for heating and once for cooling) would be ideal.
What are the signs that I need to replace my HVAC system?
Frequent breakdowns, rising energy bills, and fluctuating indoor temperatures are all strong signs that it’s time for an HVAC system replacement.
How can I improve my home's indoor air quality?
Keep the house well-ventilated by opening the windows and using fans. You can also use air purification devices, and avoid smoking or using products that contain volatile organic compounds (VOCs).
What should I do if I have a clogged drain?
Try using a plunger or a chemical drain cleaner. If that doesn’t work, it’s best to call a professional plumber.
Â
Have you Seen Us in Arnold?
Classic Aire Care’s van with the family of penguins is easily one of the most recognizable vehicles in Jefferson County. Below is a map showing where our family of penguins have been recently!Â
Recent Jobs and Reviews in Arnold, MO
Arnold, MO at a glance
Classic Aire Care has completed 20 jobs in Arnold, MO between June 2026 and July 2026.
The most recent job was on July 1, 2026.
Classic Aire Care has completed 168 jobs in Arnold, MO in the last 12 months.
Job Locations and Reviews
Responded to no-cool complaint on 10+ year old outdoor unit located in backyard. Upon arrival, found fan blade had catastrophically failed, breaking off and striking condenser coil on all four sides causing significant impact damage. Performed thorough inspection of condenser coil for refrigerant leaks using leak detection methods and pressure testing. Assessed internal components including evaporator coil assembly and refrigerant lines for secondary damage. Documented extensive damage to unit housing, condenser fins, and mounting brackets with photographic evidence. Contacted customer to discuss findings regarding system repairability versus replacement options given age of equipment and extent of damage. Unit remains non-operational pending customer decision on repair authorization.
# HVAC Service - No Cool Call Responded to no cooling complaint on 10+ year old AC unit located at side of home. Upon arrival, confirmed unit was shut down due to suspected blower motor failure. Performed diagnostic testing on blower motor assembly using multimeter to verify electrical continuity and motor functionality. Inspected blower housing, motor connections, and wiring harness for signs of failure or damage. Motor showed signs of age with significant dust accumulation on housing and internal components. Tested electrical connections at motor terminals and verified proper voltage supply to unit. Documented existing condition of blower motor assembly and electrical connections with photos for service records. Provided customer with diagnostic findings and repair recommendations to restore cooling operation.
Responded to customer report of strong odor emanating from air conditioning unit. Performed diagnostic inspection of 10-year-old ground-level AC system located at rear of property. Inspected ductwork and HVAC components, documenting conditions with photos for service records. Identified source of malodor and addressed issue to restore normal system operation.
Responded to service call for HVAC system and water heater assessment following reported flood damage. Performed visual inspection of outdoor condenser unit and basement mechanical systems to evaluate operational status and extent of water damage. Documented current condition of equipment including condenser unit, ductwork, water heater, and associated plumbing infrastructure to confirm system functionality concerns.
Completed comprehensive AC tune-up on single outdoor unit located in side yard. Performed standard maintenance protocol including inspection of electrical components, transformer, and wiring connections within cabinet. Unit is original equipment approximately 58 years old, showing age-related wear and dust accumulation in electrical compartment. Cleaned and serviced accessible components, verified proper operation of all systems. Custom-cut filter material installed in furnace per specifications due to non-standard sizing requirements of original equipment. All safety checks completed and unit returned to normal operation.
Completed cooling season tune-up on single AC unit located in hallway. Performed comprehensive system inspection including evaporator coil assessment, which revealed significant dust and debris accumulation on coil surface and fins requiring attention for optimal heat transfer efficiency. Evaluated customer-installed thermostat per special request to diagnose reported operational issues. Inspected refrigerant lines, drain pan assembly, and all accessible HVAC components. Documented equipment condition with photos showing evaporator coil assembly, heat exchanger fins, refrigerant piping, and filter housing. System operational upon completion of maintenance procedures.
Responded to no cooling call on 10+ year old unit located at side of home. Upon arrival, performed system diagnostics using refrigerant manifold and micron gauge, which revealed significant pressure imbalance with low-side reading at 7.107 psia and high-side reading at 126 psia, indicating critically low refrigerant charge in R410A system. Diagnosed refrigerant leak as root cause of cooling failure and advised customer of findings and repair options needed to restore proper system operation.
# HVAC Tune-Up Service Completed Performed comprehensive preventive maintenance tune-up on residential HVAC system under Home Depot service agreement. Conducted electrical diagnostics using Fieldpiece SC680 True RMS multimeter, measuring system amperage at 0.74A and verifying proper voltage levels. Recorded outdoor ambient temperature of 40.63°F during service call. Updated equipment age documentation and confirmed unit serial number for service records. System operating within normal parameters with no accessories requiring replacement at this time.
Responded to no cooling complaint on 2-year-old central air conditioning system. Upon arrival, confirmed system was running but not producing cold air to conditioned space. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler components. Utilized refrigerant manifold gauges and micron measurement equipment to assess system pressures and refrigerant charge levels. Inspected blower motor assembly and ductwork connections at indoor unit for proper operation and airflow. Measurements indicated refrigerant system anomaly requiring pressure testing and charge verification. Documented equipment conditions and diagnostic readings for service records.
Responded to no cooling call on 20+ year old Lennox whole-house air conditioning system. Upon arrival, performed diagnostic assessment of outdoor condensing unit. Utilized manifold gauges to check refrigerant pressures and system operation. Documented equipment condition and test results with photos for service records. Completed troubleshooting procedures to identify root cause of cooling failure and provided recommendations for system repair or replacement given age of equipment.
Responded to no cooling complaint on 10+ year old ground-level unit located at back of home. Upon arrival, performed diagnostic evaluation using refrigerant manifold and micron gauge to assess system pressures and operation. Inspected air filter and found restricted airflow condition. System pressures indicated 232.5 PSI high side and 21.8 PSI low side with ambient conditions present. Completed full system diagnostics and documented equipment conditions with photographic evidence for service records.
Responded to no cooling complaint on residential outdoor HVAC unit. Upon arrival, found system blowing warm air as reported. Performed diagnostic inspection and discovered severely clogged air filter with heavy accumulation of dirt, dust, and debris restricting airflow. Removed contaminated filter from unit housing and replaced with new filter. Verified proper airflow restoration and system operation. Unit returned to normal cooling function. Advised customer on recommended filter maintenance schedule to prevent future airflow restrictions.
# HVAC Service Completed Responded to no-cooling call where condenser unit would not turn on. Upon arrival, performed diagnostic testing of the outdoor unit's electrical system. Pressure readings indicated system had refrigerant charge present. Investigation of the control panel revealed a failed dual-run capacitor rated at 35/5 MFD. Replaced defective capacitor with new TITAN PRO TRCFD3554 unit matching original specifications. Verified proper electrical connections to compressor and condenser fan motor circuits. Tested system operation and confirmed condenser unit now starting properly with normal amp draws. Unit restored to full cooling operation.
Responded to no cooling complaint with indoor temperature at 81°F and system running continuously. Upon inspection, found outdoor condensing unit with heavily weathered copper refrigerant lines and aged electrical connections showing significant environmental exposure. Performed diagnostic evaluation of outdoor unit components, inspected condenser coil fins through louver grille, and assessed overall system condition. Unit displayed substantial dirt and debris accumulation on both internal and external components. Documented equipment condition with photographs showing corroded piping, aged wiring, and compromised connections at outdoor unit. Completed system assessment for elderly residents requiring immediate cooling restoration.
Responded to service call for multiple electrical issues including non-functional water heater traced to electrical panel problem, replaced bathroom light fixture, resolved flickering bedroom light, and diagnosed basement fluorescent fixture that remained inoperative after customer's tube replacement attempt. Inspected and serviced main electrical panel, addressing circuit breaker connections affecting water heater operation, and completed fixture replacements and lighting repairs throughout residence.
Responded to no-cooling call where outdoor unit fan would not operate while indoor blower ran normally. Upon arrival, performed diagnostic testing on outdoor unit components including capacitor and electrical connections. Inspected outdoor disconnect and wiring at exterior wall-mounted junction, noting weathered connections and corroded terminals. Tested dual run capacitor which showed insufficient microfarad reading on fan circuit. Replaced failed capacitor, verified proper fan motor operation, and confirmed system cooling functionality. Cleaned electrical connections and ensured secure wire terminations at disconnect box before restoring full system operation.
Responded to first-time service call for refrigerant leak search on basement air conditioning unit following previous maintenance visit that identified possible evaporator coil leak. Performed comprehensive leak detection using electronic leak detector and pressure testing equipment on system. Utilized digital manifold gauges to monitor system pressures and temperatures throughout diagnostic process to pinpoint source of refrigerant loss.
Responded to no cooling complaint on 9-year-old AC system where capacitor had been replaced by another contractor earlier same day but unit still not cooling. Upon arrival, thermostat displayed 82°F with supply air temperature at 77°F. Performed comprehensive diagnostic evaluation of entire system. Found compressor attempting to start but failing to run continuously. Identified additional electrical issue preventing compressor operation beyond the previously replaced capacitor. Diagnosed failed contactor with burned contacts preventing proper power delivery to compressor. Replaced defective contactor with OEM replacement part. Verified proper voltage and amperage draw to compressor. Tested system operation through complete cooling cycle. Confirmed compressor running smoothly with proper start-up and continuous operation. Measured supply air temperature drop, verifying adequate cooling performance. System restored to normal operation with proper temperature differential across evaporato
Performed comprehensive furnace inspection on 10-year-old Goodman GMVC80805CN unit located in basement following reported concerns about previous leak affecting system operation. Accessed blower compartment and control board assembly, visually inspected all electrical connections, wiring harnesses, and control boards for signs of water damage or corrosion. Examined condensate drain line and flexible drain hose for proper routing and functionality. Verified all safety labels present and legible, confirmed air filter condition, and inspected ductwork connections for integrity. All components found to be functioning properly with no evidence of leak-related damage to electrical systems or controls.
Responded to no cooling call and found unit with frozen evaporator coil that had been shut off prior to arrival. Performed diagnostic evaluation using refrigerant manifold gauges to assess system pressures and temperatures, with readings showing 38.3°F and 56.3°F temperatures and 18.79 PSI on the outdoor condensing unit. Allowed system to thaw completely before conducting further diagnostics to determine root cause of freezing condition and provided temporary cooling solution until scheduled equipment replacement.